Home > Product Information > Drilling & Completion > IBOP Tools
  1. IBOP Tools
  2. IBOP Tools
  3. IBOP Tools

IBOP Tools

Our IBOPs can be applicable to Top Drives from domestic and foreign brands such as BPM, TPEC, VARCO, TESCO, CANRIG and etc. We can produce H2S free IBOP with high requirements by using imported superior anti-H2S materials.

  1. Detailed information

IBOP For Top Drive (Upper/Lower Safety Valves)

IBOP for top drive can be divided into Upper IBOP and Lower IBOP; they are control valves which are used with the top drive system. Usually the two valves connected to the top drive drilling device. The IBOP adopts high reliable metal seal. Soit can bear high pressure upward and downward. The working pressure can be achieved 10000 psi or 15000 psi. When well kick occurring, the upper IBOP can be closed by remote controlled, but the lower IBOP will be closed manually. Actuator for top drive is a subsidiary body which controls open and close of Upper IBOP. It works with other accessories of the rig, so that control openning and closing of Upper IBOP on any height of derrick driller console. Both the valve body cavity and accessories have special anticorrosive processing, so that prolong the working life.

Specification

Model

OD

mm(inch)

ID

mm(inch)

OAL

mm(inch)

Connection API

JC3M

187 (7 23/64)

78 (3 5/64)

572 (22 33/64)

6 5/8REG BOX & BOX

JC3J

187 (7 23/64)

78 (3 5/64)

523 (20 19/32)

6 5/8REG BOX & PIN

JC187-3C

187 (7 23/64)

76.2 (3)

572 (22 33/64)

6 5/8REG BOX & BOX

JC187-4

187 (7 23/64)

76.2 (3)

523 (20 19/32)

6 5/8REG BOX & PIN

JC190-1

190 (7 31/64)

76.2 (3)

547 (21 17/32)

6 5/8REG BOX & PIN

JC196-1

195.8 (7 45/64)

78 (3 5/64)

572 (22 33/64)

6 5/8REG BOX & BOX

JC196-2

195.8 (7 45/64)

78 (3 5/64)

523 (20 19/32)

6 5/8REG BOX & PIN

JC197-5C

197 (7 3/4)

76.2 (3)

572 (22 33/64)

6 5/8REG BOX & BOX

JC197-6B

197 (7 3/4)

76.2 (3)

536 (21 7/64)

6 5/8REG BOX & PIN

JC197-3

197 (7 3/4)

78 (3 5/64)

584 (23)

6 5/8REG BOX & PIN

JC197-4

197 (7 3/4)

78 (3 5/64)

512 (20 5/32)

6 5/8REG BOX & PIN

JC200-2

200 (7 7/8)

76.2 (3)

547 (21 11/32)

6 5/8REG BOX & PIN

JC216-1

216 (8 1/2)

78 (3 5/64)

600 (23 5/8)

6 5/8REG BOX & PIN

JC216-2

216 (8 1/2)

78 (3 5/64)

533 (20 63/64)

6 5/8REG BOX & PIN

JC216-4

216 (8 1/2)

76.2 (3)

603 (23 47/64)

6 5/8REG BOX & PIN

JC254-3

254 (10)

105 (4 9/64)

596 (23 15/32)

6 5/8REG BOX & PIN

Top Drive Saver Sub

Top Drive Saver Sub is a kind of sub connected with Lower IBOP and drill pipe, mainly used in the top drive system. Not only acting as crossover sub, but also protecting lower IBOP. Top drive saver sub can be divided into general top drive saver sub and low temperature top drive saver sub.

Specification

Model

OD

mm(inch)

ID

mm(inch)

Conn.

TDC187B

187(7 23/64)

57.2(2 1/4)

6 5/8REG×NC46

TDC187A

187(7 23/64)

71.4(2 13/16)

6 5/8REG×NC50

TDC197B

197(7 3/4)

57.2(2 1/4)

6 5/8REG×NC46

TDC197A

197(7 3/4)

71.4(2 13/16)

6 5/8REG×NC50

TDC219A

219(8 5/8)

71.4(2 13/16)

7 5/8REG×NC50

MetInfo enterprise content manager system | MetInfo CMS

IBOP Actuator

Actuator is a driving tool supporting the use of top drive system, and it consists of actuator and crank. It drives the actuator by the top drive hydraulic system, and the actuator controls open and close of the inner ball valve in Upper IBOPs by rotating of crank mechanism. It is reliable to work and easy to handle.

Specification

Working with φ187,φ197,φ216 IBOP for top drive.

MetInfo enterprise content manager system | MetInfo CMS  MetInfo enterprise content manager system | MetInfo CMS               

                                                                                                               Actuator                      Crank

Inside BOP Valve

 MetInfo enterprise content manager system | MetInfo CMS

Inner Blowout Preventer is a necessary blowout preventing device during drilling process specified by IADC (International Association of Drilling Contractors). If any well kick or overflow occurs, the inner blowout preventer shall be used, because the important thing at this moment is to land the drilling rods into the well as many as possible, and this can be done only by installing a pressure-returning device in the drill string.

Model

O.D mm (in)

Connection

Pressure grade (Mpa)

NFQ105

105 (4 1/8)

NC31

70, 105

NFQ127

127 (5)

NC38

70, 105

NFQ159

159 (6 1/4)

NC46

70, 105

NFQ168

168 (6 5/8)

NC50

70, 105

NFQ178

178 (7)

5 1/2FH

70, 105

NFQ184

184 (7 1/4)

5 1/2FH

70, 105

Continuous Circulating Valve

MetInfo enterprise content manager system | MetInfo CMS

Continous circulating valve is a kind of key tools used in continuous circulating well-drilling technology. The purpose is to solve a series of problems under the well caused by annulus pressure fluctuation due to the stop/start the circulation when unloading a single column during the well-drilling and stripping-in process.

Model

Tool O.D

Length

Water Hole Diameter

Connection

Max. Working Load

mm(in)

mm

mm(in)

API

kN(1bf)

LXF133

133.4(5 1/4)

680

50(2)

NC38

1722(387000)

LXF178

178(7)

760

71.4(2 3/4)

NC50

2828(636000)

LXF203

203 (8)

760

71.4(2 3/4)

NC50

2852(640000)

Multi-Stage By-pass Valve

 MetInfo enterprise content manager system | MetInfo CMS

Multi-Stage By-pass Valve are active in different ways of drilling, it is assembled at the back of power tools (such as drilling motor, turbo drilling tool, MWD, LWD etc) and can achieve five by-pass cycling times. It can prevent and reduce rock debris during application in large displacement and horizontal wells. Besides, when injecting plugging agent it can prevent the agent from flowing inside to the power tools, which can reduce lifting times and save costs.

Model

Tool O.D. mm

Tool I.D. mm

Connection

By-pass Hole Dia. mm

Length

Ball Dropping times

DPF121

121

50

NC38

27

1560

5

DPF165

165

70

NC50

38

1560

5

DPF172

172

70

NC50

38

1560

5

DPF203

203

76

6-5/8 REG

38

1700

5

DPF241

241

76

7-5/8 REG

44

1800

5

Float Valve Core

MetInfo enterprise content manager system | MetInfo CMS

In normal well-drilling, the valve cover of the floating valve core opens, then the drilling fluid circulates smoothly. When the well kick or blowout occurs under the well, the valve cover is closed so as to reach the purpose of blowout prevention, which can prevent the drilling fluid backflow, and prevent the sediment from getting into the drill string to get anti-blocking effect during stripping-in operations.

“G” Type Valve Core

Model

Length mm

Core O.D mm

Core I.D mm

Pressure Mpa

1R

149

42.06

20

35-105

1F-2R

159

48.4

28

35-105

2F-3R

165

61.1

32

35-105

3F

254

71.4

40

35-105

3 1/2IF

254

79.3

40

35-105

4R

211

88.1

50

35-105

5R

247.6

98.4

60

35-105

5F-6R

298

121.4

76

35-105

“F” Type Valve Core

Model

Length mm

Core O.D mm

Core I.D mm

Pressure Mpa

Working Hours

1R

149

42.06

27

35-105

350-400

1F-2R

159

48.4

32

35-105

350-400

2F-3R

165

61.1

32

35-105

350-400

3F

254

71.4

50

35-105

350-400

3 1/2IF

254

79.3

50

35-105

350-400

4R

211

88.1

64

35-105

350-400

5R

247.6

98.4

70

35-105

350-400

5F-6R

298

121.4

85

35-105

350-400

Highlights: The operation life for standard valve core is around 200 hours.

And operation life for High-Efficiency Valve Core can reach to 500 hours.

Throw-Type Back Pressure Valve

Arrow Back-Pressure Valve

Double Function Arrow-shaped Back Pressure Valve

MetInfo enterprise content manager system | MetInfo CMS

MetInfo enterprise content manager system | MetInfo CMS

MetInfo enterprise content manager system | MetInfo CMS

Kelly & Top Drive Plug

Float Sub

Full Open Safety Valve

MetInfo enterprise content manager system | MetInfo CMS

MetInfo enterprise content manager system | MetInfo CMS

MetInfo enterprise content manager system | MetInfo CMS

Powered by MetInfo 5.3.8 ©2008-2024 www.metinfo.cn